(AMP)One Step Amphetamine Test

Home > (AMP)One Step Amphetamine Test
Previous
Next

(AMP)One Step Amphetamine Test

The One-step Amphetamine Test is a lateral flow, one-step immunoassay for the qualitative detection of amphetamine in human urine at a cut-off of 1000ng/ml. This product is used to obtain a visual, qualitative result and is intended for professional use.The assay should not be used without proper supervision and is not intended for over the counter sale to lay persons.

Description:

SENSITIVITY OF THE TEST

MOP-300ng/ml, MET-1000ng/ml, KET-1000ng/ml, MDMA-500ng/ml, COC-300ng/ml, THC-50ng/ml, 

AMP-1000ng/ml, BAR-300ng/ml, BZO-300ng/ml, MTD-300ng/ml, PCP-25ng/ml, BUP-10ng/ml, 

TCA-1000ng/ml, OXY-100ng/ml, PPX-300ng/ml, OPI-2000ng/ml.

Quality Standards:

CE, Declaration of Conformity

Product Performation:

TEST PROCEDURE(Strip)

1.Bring the pouched test strip to room temperature (15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test strip from the sealed pouch.
3. Immerse the test strip in the urine specimen with the arrow end pointing toward the urine. Do not immerse the strip above the printed MAX line.
4. After a minimum of 15 seconds, remove the test strip from the urine and lay flat on a non-absorptive clean surface. Alternatively , leave the test strip in the urine specimen as long as the strip is not immersed above the MAX line.
5. Read results between 3-8 minutes. Do not read results after 10 minutes.

Interpreting results( Strip)

Negative: Two red lines are visible, one in the test region (T) and another one in the control region (C). No matter the color intensity of the test line is weaker or stronger than that of the control line, the test result is negative.

 

Positive: Only one red line visible in the control region (C) and the absence of the test line indicates a positive result.

 

NOTICE: A very faint line in the test region indicates that the amphetamine in the specimen is near the cut-off level of the test. These specimens should be retested or confirmed with a more specific method before a positive determination is made.

 

Invalid: The test is invalid if the control line is not visible regardless of the presence or absence of the test line.

Interpreting results( Cassette)

Negative: Two red lines are visible in the result window. The line in the test region (T) is the test line and the line in the control region (C) is the control line which is used to indicate proper performance of the device. No matter the color intensity of the test line is weaker or stronger than that of the control line, the test result is negative.

Positive: Only one red line visible in the control region (C) and the absence of the test line indicates a positive result.

NOTICE: A very faint line in the test region indicates that the amphetamine in the specimen is near the cut-off level of the test. These specimens should be retested or confirmed with a more specific method before a positive determination is made.

Invalid: The test is invalid if the control line is not visible regardless of the presence or absence of the test line.

Video